TCOMSYS01 Hot Cube Thermal comfort measuring system: User's Manual Datasheet

Introduction

TCOMSYS01 was originally designed to study the effect of radiation sources on human comfort. Equipped with heat flux sensors that measure in 5 directions and a humidity and temperature probe, it offers a good picture of energy gains and losses from all sides to a metal body that thermally resembles the human body; the TCOM01 sensor is in essence a miniature thermal mannequin.

The TCOMSYS01 system employs dedicated sensors and electronics, measuring thermal comfort according to the new Hot Cube method. The high accuracy of the MCU (Measurement and Control Unit) ensures that TCOMSYS01 will still measure down to very low heat fluxes. The MCU has a robust aluminum housing. The system generates a measurement file, including a time-stamp. The measurement data are stored in the MCU and are later downloaded to a PC. The user is responsible for data analysis.

How to employ TCOMSYS01

The primary source of information from TCOMSYS01 simply is the power [W] required to keep the TC0M01 sensor at a constant temperature; a very direct measure of human comfort. This power may be compared to the power required at 20 °C ambient air temperature, no convection (zero wind speed), and no radiation. Power consumption will immediately show if there is a situation of overheating or heat stress or a situation of overcooling or cold stress.

The second direct information supplied by the heat flux sensors of TCOMSYS01 is the heat loss or gain [W/m2] as a function of direction. If radiative sources are dominant, TCOMSYS01 will measure radiative asymmetry.

To study the exact effect of radiative sources, in many cases a simple experiment, like switching a radiation source [on] and [off] or shielding a radiation source, can be used to distinguish between convective and radiative heat transport.

Far-infrared radiation sources may be studied by temporary shielding with a silicon wafer. Silicon has around 50 % transmission. Radiation from the sun or lamps may be quantified by shading and unshading.

To study the insulating effect of clothing, TCOM01 may be insulated using the same fabrics.

A web browser may be used for real-time measurement review, data collection, and for changing control settings such as TCOM01 body temperature.

History

Already in 1929 the Eupatheoscope (from Greek “wellbeing–emotion–examination”) was designed by A.F. Dufton to quantify the condition in a room from the point of view of comfort. It consists of a blackened cylinder that is controlled to maintain a temperature of 23 °C. The power used is interpreted in terms of equivalent temperatures.

In 1990 the company Bruel & Kjear carried a thermal comfort meter (model 1212), based on the same principle, in addition to processing Fangers equation.

Both models involved only an integrated power measurement. The new Hot Cube method improves on this by incorporating omnidirectional heat flux measurements.

What makes TCOMSYS01 different?

The main contributors to thermal comfort are air temperature, airspeed, radiant temperature, and humidity. Apart from this, there are personal contributors such as metabolic rate and insulation by clothing.

Many studies use Fanger’s thermal comfort equation as applied in EN ISO 7730: Moderate Thermal Environments – Determination of the PMV and PPD indices and specification of the condition for thermal comfort. Another approach utilizes a globe temperature measurement: EN ISO 27243: Hot environments. Estimation of the heat stress on working man, based on the WBGT Index (Wet Bulb Globe Temperature).

These methods are quite indirect in particular when determining the heat flow from airspeed and radiation.

  • offers heat flux measurements. This approach is a lot more direct than the indirect estimate from airspeed and radiation.
  • TCOMSYS01 offers directional information.
  • TCOMSYS01 works at a realistic skin temperature of 33 °C (user adjustable).
  • Rated operating conditions

    TCOMSYS01 is designed to work between +10 and +25 °C. In its standard configuration, uninsulated and stabilized at 33 °C, it is rated for operation in indoor conditions including significant radiative heating.

    It will stabilize at 33 °C under approximately one of the following conditions:

  • air speeds < 5 m/s
  • irradiance < 400 W/m2
  • ambient air temperature > 5 °C
  • Under other conditions, the sensor may not be able to stabilize its body temperature due to overheating (indicating overheating or heat stress) or shortage of electrical power (indication of overcooling or cold stress). Powered using a low voltage, TCOMSYS01 is safe to use.

    TCOMSYS01 may be used for short-term outdoor experiments in the order of weeks. Under long-term exposure to solar radiation, the black heat flux sensor coating may become more reflective.

    User interface: MCU is a web server

    he MCU serves as a web server and can be connected to any local area network. No more downloading USB drivers and special interface software! Alternatively, it offers an “Ethernet over USB” or virtual Ethernet link, where you connect to the MCU using a USB cable. If you type into your web browser the MCU’s IP address (192.168.66.1 by default), you have access to the user interface.

    Ordering the TCOM01 sensor only

    The sensor TCOM01 is also available as a “sensor only”; The configuration then includes the mannequin with 5 x heat flux, 1 x temperature, 1 x heater, 2 x cable, 2 x chassis connector, and 1 x tripod. The user then must combine it with his or her own measurement and control unit.

    Suggested Use

  • surveys of human thermal comfort
  • studies of the effect of radiating sources
  • workplace investigations
  • car passenger comfort testing
  • educational purposes, illustrating heat transfer
  • bio-meteorology
  • microclimate studies
  • wind-chill analysis
  • analysis of fabric insulation
  • Areas of Application

  • Building physics / insulation, thermal comfort, and energy budget measurement
  • TCOMSYS01 Hot Cube Thermal comfort measuring system Specifications:

    Measurand heating power for stabilization, heat flux (5x), ambient air temperature, relative humidity, TCOM01 body temperature
    TCOMSYS01 specifications :
    TCOM01 temperature setting 33 °C (user adjustable)
    Included cable 2 x cable with 2 connectors (1.5 m)
    Standard rated operating temperature range +10 to +25 °C
    Limiting temperature range – 25 to +50 °C
    Required data analysis To be performed by the user
    Data display in web browser
    Start up interval < 10 min
    TCOM01 specifications :
    Weight 1.12 kg
    Temperature sensor 10 kΩ thermistor
    IP protection class IP65
    Mounting tripod with ? inch -20 UNC screw; a Manfrotto Pixi EVO 2-section tripod is included
    MCU specifications :
    User interface on MCU as a web page
    Connection via LAN or “Ethernet over USB”
    Voltage measurement accuracy 4 x 10-6 V (0.8 W/m2)
    Rated power supply voltage 10 to 16 VDC
    Adapter power supply 100 – 240 VAC, 50/60 Hz
    Rated operating temperature range MCU – 25 to +50 °C
    Data storage capacity 2GB; > 1 year of data
    Options 2GB; > TCOM01 sensor only extended rated operating conditions; temperature, irradiance, wind speed

    WeChat

    Customer Service QQ

    Customer Hotline:

    010-52867770
    0l0-52867771
    l3811111452
    l7896OO5796

    Technical Supports

    0l0-52867774
    l7896OO5796
    info@dorgean.com
    主站蜘蛛池模板: www欧美在线 | 日韩视频中文字幕在线观看 | 日韩精品中文字幕一区二区 | 久久看片 | 欧美肥妇毛多水多bbxx | 伊久久| 成人性做爰 | 在线aaa | 91亚色| 中文字幕淫 | 日本丰满老妇bbw | 天美传煤毛片 | 免费在线毛片 | 国产亚洲精品一区二三区 | 激情五月婷婷 | 黄色片久久久久 | 免费国产午夜理论片不卡 | 日本欧美亚洲中文在线观看 | 欧美少妇b | 久久婷婷五月综合色俺也想去 | 91手机在线观看 | 国产精品伦视频 | 伊人365影院 | 日韩v亚洲v欧美v精品综合 | 肉岳疯狂69式激情的高潮 | 永久免费看动漫黄址 | 国产精品久久二区二区 | 99热视 | 超级碰在线观看 | 日韩丰满少妇无码内射 | 色婷婷久久综合中文久久蜜桃av | 男人的天堂国产在线视频 | 欧美gif抽搐出入又大又黄 | 国产亚洲精品影视在线 | 亚洲色图40p| 91在线亚洲 | 大陆一级黄色片 | 亚洲人妖女同在线播放 | 在线观看成年人视频 | 高潮毛片无遮挡高清视频播放 | 色欲综合久久躁天天躁蜜桃 | 99久久免费看精品 | 久久和欧洲码一码二码三码 | 中文字幕乱码一区av久久不卡 | 天天躁日日躁狠狠躁欧美老妇小说 | 黑人强伦姧人妻日韩那庞大的 | 国产网站免费在线观看 | 无码一区二区三区免费 | 久久av老司机精品网站导航 | 日韩亚洲国产中文永久 | aaa级黄色片 | 男女一进一出超猛烈的视频不遮挡在线观看 | 欧美网站在线观看 | 一区二区三区鲁丝不卡麻豆 | 一级又爽又黄的免费毛片视频 | 国产丝袜在线精品丝袜不卡 | 六月天婷婷 | 久久综合日本 | 色婷婷av久久久久久久 | 国产免费av网址 | 亚洲人成电影在线观看网色 | 亚洲成人免费在线 | 免费a在线观看播放 | 国产美女被遭强高潮网站不再 | 偷拍一区二区三区在线婷婷 | 一本一道a∨波多野极衣 | 国产午夜性春猛交ⅹxxx | 人妻被按摩到潮喷中文不卡 | 国产精品新婚之夜泄露女同 | 国产超碰91| 香蕉久久一区二区三区 | 国产精品久久久久久免费免熟 | 台湾佬美性中文网 | 日韩在线一区二区三区 | 日韩精品一卡2卡3卡4卡新区乱码 | 大奶子情人 | 久久六六| 强被迫伦姧在线观看无码 | 无码欧美毛片一区二区三 | 男女做爰猛烈啪啪吃奶伸舌头下载 | 国产又黄又湿又刺激网站 | 国产一区二区三区免费观看在线 | 99久久精品美女高潮喷水 | 成人午夜免费毛片 | 日本午夜大片 | 国内午夜熟妇又乱又伦 | 东京道一本热中文字幕 | 国产又爽又黄又舒服又刺激视频 | 亚洲短视频 | 日韩 国产 在线 | 亚洲天堂成人网 | 春色伊人 | 东京热无码av男人的天堂 | 国产男女视频网站 | 少妇扒开双腿让我看个够 | 夫妻性生活黄色大片 | 亚洲色偷拍另类无码专区 | 三个男人躁我一个爽视频免费 | 97精品国产97久久久久久春色 |