ZGC Zero Gauss Chamber Description:

The model ZGC zero gauss chamber reduces the environmental magnetic field (Earth field) to near zero inside the chamber. Any gaussmeter probe which is less than 9.4 mm or 0.370″ diameter can be placed inside. The meter is then “zeroed”, which means that it will read zero whenever the probe is subsequently placed in zero field. By using a zero gauss chamber, any offset error is therefore eliminated. The model ZGC is unique in that it contains a degausser (demagnetizer). This is situated between the inner and outer mu-metal shields. When the degauss button is pressed, any accidental magnetization of the chamber, no matter how strong, is erased. Accidental magnetization is a major problem with most zero gauss chambers and it has limited their use. If a magnet comes too close, the chamber will become “permanently” magnetized and will have an internal field that is typically 0.2 to 0.5 gauss. The chamber must then be degaussed because the Earth field is also around 0.5 gauss, so a magnetized zero gauss chamber will not significantly reduce the field.

Demagnetizing a zero gauss chamber with an external degausser is difficult, even if a degausser is available. Often an external degausser is not strong enough to erase the magnetism of the inner shield, and using a degausser (which is fairly large) is not convenient. When using the ZGC, a single press of the degauss button brings the internal field to less than 0.01 gauss (in all three axes) within a 5 mm wide x 9.4 mm diameter region in the center of the chamber. While the battery is connected, no power is consumed except when the degauss button is being pressed. Even then, a typical 9 volt battery (included) can power over 10 million degauss cycles. After degaussing, the field is < 0.01 gauss regardless of the orientation of the chamber (within the Earth field). If the long axis of the chamber (left-right direction in photo below) is specifically oriented east-west during the degauss, the internal field will be < 0.002 gauss, although most gaussmeters do not require that degree of precision.

The white cylindrical spacer (shown in hand below) is included. It is used as a “stop” to center most gaussmeter probes in the zero gauss region. It allows the end of a probe to be inserted 1.6 mm past the centerline of the chamber. This is the appropriate distance for exact centering of all AlphaLab gaussmeter probes, including axial, transverse, universal and 3-axis. The spacer can be inserted in either side (the chamber is symmetric).

AlphaLab Zero Gauss Chamber (ZGC) Instructions

The white plastic part (spacer) can be removed at any time, but it should be used if you want to center a gaussmeter probe inside the chamber. When placed in either end, this white spacer will allow the end of a probe to be inserted exactly 1.6 mm past the center of the chamber. Therefore the actual sensor for AlphaLab models VGM, GM-2, GM-3, 1-ST and 1-HS will be properly centered in the chamber. The zero gauss region has diameter 9.4 mm (0.370”) and occupies the center 5 mm (0.197”) within the chamber. (The chamber dimension in its long axis is 36 mm, or 1.42”). In the center 5 mm, the magnetic field is < 0.01 gauss after pressing the black degauss button, regardless of the orientation of the chamber. It will remain < 0.01 gauss as long as the chamber is not rotated more than 30 degrees from its orientation when degaussed. (Note that this specification is valid if the field outside is < 0.6 gauss, which is characteristic of the Earth field.) Insert the gaussmeter probe as shown below and zero the gaussmeter.

The field inside the chamber can be reduced to < 0.002 gauss (2 milligauss) if the long axis is oriented the east-west direction when the degauss button is pressed, and if the chamber is kept in that orientation. However, 0.002 gauss accuracy is not necessary for most gaussmeters, which generally read down to 0.01 or 0.1 gauss.


As with any zero gauss chamber, exposure to a magnet or strong field (> 5 gauss) will “permanently” magnetize the chamber. For the model ZGC, this permanent internal field can be as high as 0.2 gauss after being exposed to a strong field. Any such chamber will then have to be degaussed to erase this effect. The ZGC has a built-in degausser, which will reduce the field as specified above. For fields above 0.6 gauss, 1.5% of the field component parallel to the long axis of the chamber will leak into the chamber. For the other two axes (perpendicular to the long axis), magnetic field leakage is < 0.2%. For comparison, the Earth field is between 0.2 and 0.6 gauss. The ZGC will only remagnetize if it is exposed to a magnet again. To degauss, snap a 9 volt battery to the case and press and hold the small button for at least 1/4 second. For the lowest possible internal field, the long axis be pointing east-west (or in a direction with low field: less than 0.05 gauss) during degaussing.

The battery can remain connected because it draws no power unless the button is being held down. Even while the button is pressed, current consumption is about 0.05 ma, and the battery can last over 6 months at that load. The steel case of most 9 volt batteries may be unwanted in a low-gauss area, so the battery is easily disconnected. Standard batteries, if magnetized, may allow as much as an extra 0.001 gauss to leak inside the ZGC. If very low field is required, attach the battery for at least 2 seconds to charge the internal one microfarad degaussing capacitor. Then remove the battery to degauss. All of the energy for one degauss cycle is stored in the capacitor and the capacitor will remain charged for >10 minutes. Degaussing is complete (and the capacitor becomes completely discharged) within 1/10 second after pressing the degauss button.

To get a very low field, it was mentioned above that the ZGC should be degaussed while the long axis of the chamber (left-right direction of the label text) is pointed east-west so that the field in that direction is < 0.05 gauss. To verify that the east-west direction is < 0.05 gauss, or to find a direction that is low-field, select a direction and measure the field in that direction with a gaussmeter. The meter does not need to be correctly zeroed. For 3-axis gaussmeters such as the VGM or GM-3, examine only a single axis, such as Z, and point that axis of the probe toward the selected direction. Then point the probe in the opposite direction: 180° away, and remeasure. If you have chosen a low-field direction, these two numbers should be the same, or at least within 0.1 gauss of each other.

The proper functioning of the chamber (i.e., whether it is approximately true zero) can be independently verified with a gaussmeter even if the gaussmeter is not zeroed. To verify zero in the long axis of the chamber, examine the Z field with a VGM or GM-3 meter, or use an axial probe with a single-axis gaussmeter model. (With single-axis models, verifying the long-axis zero is irrelevant if your probe is either transverse or universal). Degauss and orient the ZGC east-west as above. Use the white plastic spacer as a stop; insert the probe and measure. Then without moving the ZGC, interchange the probe with the spacer and measure again. These numbers should be the same within the gaussmeter’s stability. To verify zero gauss in the perpendicular direction, either examine X with a VGM or GM-3 meter, or use a transverse probe or a universal probe which is not bent to an angle when verifying with a single-axis gaussmeter model. Rotate the probe 360° inside the hole. The displayed number should not change during the rotation.

ZGC Zero Gauss Chamber Specification:

Additional information:

category: Accessories

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com
主站蜘蛛池模板: 成人看片黄a免费看 | 国产亚洲精品一区二三区 | 日本高清免费在线视频 | 狠狠色网| 中文字幕人妻无码一区二区三区 | 青青操视频在线 | 亚洲黄色一区 | 国产亚洲99天堂一区 | 91久久香蕉国产日韩欧美9色 | 无码国产精品一区二区免费式芒果 | 国产免费高清视频1l.com.com.com少 | 99re热这里有精品首页 | 激情中文网| 亚洲精品一区二区三区无码a片 | 2014av天堂无码一区 | 99亚洲男女激情在线观看 | 国产精品久久久久久人妻精品18 | 亚洲精品拍拍拍在线观看 | 国产精品无码av不卡 | 国产免费爽爽视频 | 日日夜夜亚洲 | 12萝自慰喷水亚洲网站 | 久久久久青草线蕉亚洲麻豆 | 奇米影视7777久久精品 | 美女上床网站 | 久久aⅴ免费观看 | 日本国产一区 | 男人用嘴添女人下身免费视频 | 99蜜桃臀久久久欧美精品 | 久久精品国产99久久六动漫 | 天堂中文最新版在线中文 | 亚色九九九全国免费视频 | 美腿丝袜高跟三级视频 | 男女吻胸做爰摸下身 | 亚洲色欲色欲天天天www | 日韩精品久久久久久久酒店 | 2020久久超碰国产精品最新 | 国产欧美成人一区二区a片 9999热视频 奇米影视第四色7777 | 久久久综合九色综合 | 国产xxxxx视频 | 国产毛a片啊久久久久久保和丸 | 国产后入又长又硬 | 欧美精品黑人粗大破除 | 日韩一区二区三区在线免费观看 | 天天爽夜夜爽人人爽qc | 天天爽天天爽天天爽 | 成在人线无码aⅴ免费视频 一区影视 | 国产精品无码久久久久久久久久 | 国产免费网站看v片在线无遮挡 | 国产乱妇4p交换乱免费视频 | 欧美刺激性大交亚洲丶日韩 | 六月成人网 | 国产av丝袜一区二区三区 | 一本加勒比hezyo黑人 | 在线人视频观看免费 | 日韩中文字幕免费观看 | 60老熟女多次高潮露脸视频 | 国产天堂亚洲 | 欧美精品成人a区在线观看 av无码天堂一区二区三区 | 激情小说视频在线 | 国产视频一区二区三区四区五区 | 最近中文字幕在线免费观看 | 久久精品一区二区三区四区毛片 | 韩国 日本 亚洲 国产 不卡 | 国产偷v国产偷v亚洲高清 | 欧美肉大捧一进一出免费视频 | 天堂av网手机版 | 国产精品三级久久久久三级 | 无码免费h成年动漫在线观看 | 国产精品视频一区二区三区四区国 | 日本边添边摸边做边爱 | 黄色特级一级片 | 国产精品久久久久久在线观看 | 好男人免费影院www神马 | 国产一级淫片a直接免费看 亚洲乱亚洲乱妇小说网 | 狠狠躁18三区二区一区传媒剧情 | 无码日韩av一区二区三区 | 熟睡中被义子侵犯在线播放 | 国产精品成久久久久三级6二k | 欧美精品18videosex性欧美 | 波多野吉衣一区二区 | 裸身美女无遮挡永久免费视频 | 三级av在线免费观看 | 国产精品禁18久久久夂久 | 咪咪色在线视频 | 精品国产综合成人亚洲区2022 | 亚洲色偷偷色噜噜狠狠99网 | 久久婷婷五月综合尤物色国产 | 少妇把腿扒开让我添 | 美女在线国产 | 韩国毛片一区二区三区 | 好吊妞这里有精品 | 亚洲精品国产av成拍色拍个 | 超清纯大学生白嫩啪啪 | 成人97 | 欧美午夜精品久久久久久人妖 | 国产a∨国片精品青草视频 黄色免费网站观看 | 国产在线观看www污污污 | 国产在线超碰 |