LEAK CURRENT HiTESTER ST5540

Updated:2025-03-13

Views:3449

  • Brand: HIOKI
  • Model: ST5540
  • Description: The ST5540 consists of measurement networks that simulate the human body and a high-frequency volt meter, and is also capable of switching power supply polarities and making measurements under simulat
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

LEAK CURRENT HiTESTER ST5540 Description:

Orientation Pack Brochure

To ensure the safe use of electrical products, electrical safety tests such as insulation resistance, withstand voltage, ground resistance, and leakage current must always be conducted. Hioki Leakage Current Testers comply with laws and standards regarding medical electrical equipment as well as non-medical electrical equipment, and can be used to measure leakage current in all types of electrical products from computers to medical equipment.

The ST5540 consists of measurement networks that simulate the human body and a high-frequency volt meter, and is also capable of switching power supply polarities and making measurements under simulated single fault conditions in equipment under test.

Leak Current Measurement - Essential to Electrical Safety

The ST5540 series features an improved measuring method and dramatically faster cycle times thanks to its uninterrupted polarity switching capability. The new devices support rated currents of up to 20A, making it more than ideal for use with products built to new standards.

Leak Current Testing of Medical Electrical Devices

In order to prevent the danger of electric shock, electrical devices use power supplies that are isolated from parts of the device that may come into contact with the body. However, it is impossible to achieve infinite insulation resistance. Some leak current always exists, and its magnitude changes as the insulation degrades over time. The LEAK CURRENT HiTESTER ST5540/ST5541 provides an easy-to-operate solution for measuring leak current in electrical devices, making it eminently suitable for use in an extensive array of applications, ranging from production lines to equipment maintenance and inspections.

Key Features

Compliance with IEC 60601-1:2005 Ed 3.0, JIS T 0601-1:2012 for medical-use electrical devices and essential to electrical safety (*1)

Compliance with Electrical Appliances and Materials Safety Act, JIS, IEC, and UL standards for general-use electrical devices

Uninterrupted polarity switching function dramatically reduces cycle time

Support for rated currents up to 20 A gives the instrument more than adequate capability for testing products designed to comply with new standards

Communications functionality and external I/O support allow automatic testing on production lines

Basic specifications

Measurement methods Measurement of voltage drop across body simulated resistance points, Calculation and display of current values, True rms measurement, Measurement unit floats relative to instrument ground.
Measurement modes Leak current measurement, voltage measurement, safety conductor current measurement
Standards compliance
(NW: Body simulated resistance)
[NW-A] ? Electrical Appliances and Materials Safety Act
[NW-B1] ? Medical electrical equipment: IEC 60601-1:1988+ A1:1993+ A2:1995, JIS T 0601-1:1999
[NW-B2] ? Medical electrical equipment: IEC 60601-1:2005+ A1:2012, JIS T 0601-1:2012 and complement 1:2014, IEC 62353
[NW-C]
? Measurement of touch current and protective conductor current: IEC 60990:2016
? Electrical equipment for measurement, control, and laboratory use: IEC 61010-1:2010+ A1:2016
? Information technology equipment: IEC60950-1:2005+ A1:2009+ A2:2013
? Audio, video and similar electronic apparatus: IEC 60065:2014
? Personnel Protection Systems for EV: UL 2231-1:2012 (Amended 2016), UL-2231-2:2012 (Amended 2016)
[NW-D] ? For UL: UL 1492:1996 (Amended 2013)
[NW-G] ? Electrical equipment for measurement, control, and laboratory use; current measurement circuits in damp conditions: IEC 61010-1:2010+ A1:2016
Leak current measurement Ground leak current, 3 types of contact current, 7 types of patient leak current, patient measurement current, 4 types of total patient leak current, free current measurement, 3 types of enclosure leak current
Measurement current DC, AC (true rms, 0.1 Hz to 1 MHz), AC+DC (true rms, 0.1 Hz to 1 MHz), AC peak (15 Hz to 1 MHz)
Measurement ranges DC / AC / AC+DC mode: 50.00 mA/ 5.000 mA/ 500.0 μA/ 50.00 μA
AC peak mode: 75.0 mA/ 10.00 mA/ 1.000 mA/ 500.0 μA
Measurement accuracy
(current measurement)
DC measurement: ±2.0% rdg. ±6 dgt. (typ.)
AC / AC+DC measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 100 kHz, typ.)
AC peak measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 10 kHz, typ.)
Interfaces External I/O, medical device relay output, USB 1.1 (communications), RS-232C
Functionality 110% voltage application, automatic test, data storage for 100 target devices, clock, data backup, printed output (optional), etc.
Power supply 100/120/220/240 V AC (specify at time of order), 50/60 Hz, 30 VA rated power
Target device power supply input 100 to 250 V AC, 50/60 Hz Rated current input from terminal block: 20 A
Target device power supply output Output from terminal block: 20 A Output from outlet: 15 A
Dimensions and mass 320 mm (12.60 in)W × 110 mm (4.33 in)H × 253 mm (9.96 in)D, 4.5 kg (158.7 oz)
Included accessories Test lead L2200 (for ST5540, Red ×2, Black ×1) ×1 set, Enclosure probe 9195 ×1, Power cord ×3, Spare fuse for measurement line ×1, Instruction manual ×1, CD-ROM ×1

ST5540, ST5541 List of functions (Network)

Item ST5540 ST5541
Network A
(Electrical Appliances and Materials Safety Act)
Network B (Medical-use electrical devices) -
Network C (IEC 60990)
Network D (UL)
Network E (General-purpose 1)
Network F (General-purpose 2)
Network G (IEC 61010-1)

List of functions (Major functions)

Item ST5540 ST5541
Power on polarity switching function
Rated current 20 A
Function for checking for blown fuses
Frequency band switching -
110% voltage output terminal (T3 terminal) -
S10, S12, S13, E terminal -

List of functions (Testing leakage current mode)

Item ST5540 ST5541
Earth leakage current
Touch current
Patient auxiliary current -
Patient leakage current -
Total patient leakage current -
Free current
Enclosure - Earth leakage current
Enclosure - Enclosure leakage current
Enclosure - Line leakage current
Patient leakage current I -
Patient leakage current II -
Patient leakage current III -

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com
主站蜘蛛池模板: 天天爱天天射 | 久久r| 美女翘臀少妇啪啪呻吟流水 | 亚洲乱码尤物193yw | 久久久久久久性 | hsck成人网 | 久久久久人妻啪啪一区二区 | 国产一区久久 | 九九九在线视频 | 天天干天天色综合网 | 成·人免费午夜无码视频在线观看 | 欧美日韩一区二区免费视频 | 女兵的真人大毛片 | a级毛片国产 | 91制服诱惑 | 国产一级特黄a高潮片 | 超污网站在线观看 | 免费体验区试看120秒 | 91国偷自产一区二区三区水蜜桃 | av在线播放国产 | 91精品久久久久久久91蜜桃 | 天天狠天天插天天透 | 成人性做爰aaa片免费看不忠 | 欧美成人性生活视频 | 夜夜嗨网站 | 成人精品久久久 | 中文字幕一区二区精品 | 人人看人人草 | 密色av| 国产午夜福利精品一区 | 少妇与子乱毛片 | 亚洲图片中文字幕 | 亚洲精品成a人在线 | 国产精品精东影业 | 婷婷色一区二区三区 | 日本夜爽爽一区二区三区 | 日本xxxx在线观看 | 亚洲无线码中文字幕在线 | 中文精品久久久久鬼色 | 性xxx欧美老妇5060.70 | 久久精品福利视频 | 农民人伦一区二区三区剧情简介 | 欧美少妇色图 | 91视频蝌蚪 | 精品人妻一区二区三区四区 | 高潮毛片无遮挡 | 毛片视频在线免费观看 | 亚洲阿v天堂在线2017免费 | 中文字字幕在线中文乱 | 欧美精品v国产精品v日韩精品 | 亚洲一区二区三区波多野结衣 | 色久综合在线 | 日韩欧美精品一中文字幕 | 亚洲欧美洲成人一区二区三区 | 在线一区国产 | 红杏aⅴ成人免费视频 | 亚洲精品国产第一综合99久久 | 一级特级黄色片 | 中文字幕av免费 | 日韩精品一区二区三区在线视频 | 色yeye香蕉凹凸视频在线观看 | 色妞www精品免费视频 | 国产主播自拍av | 黄色美女大片 | 亚洲毛片不卡av在线播放一区 | 天堂在线精品 | 国产性―交―乱―色―情人 | 亚洲日本中文字幕 | 欧美一区2区三区4区公司 | 午夜av网址 | 91精产国品产区 | 九色琪琪久久综合网天天 | 欧美日韩欧美日韩在线观看视频 | 老色鬼永久精品网站 | 亚洲欧美视频在线 | 天干夜夜爽爽日日日日 | 欧美成人一区二区 | 91久久久久久久久久 | 亚洲 欧美 另类人妖 | 久久久久久午夜成人影院 | 亚洲天堂日本 | 国产精品久久自在自线青柠 | 欧洲无线码免费一区 | 久久久精品久久久久久96 | 中国少妇嫖妓bbwbbw | 久久精品99久久香蕉国产色戒 | 国产呻吟久久久久久久92 | 91福利在线观看视频 | 午夜无码免费福利视频网址 | 最新精品国偷自产在线婷婷 | 91激情视频在线 | 台湾佬中文字幕 | 国产白丝jk捆绑束缚调教视频 | 69黄色片| 成人午夜高潮免费视频在线观看 | 99av国产精品欲麻豆 | 精品黄色一级片 | 91精品一区二区三区在线观看 | 国产亚洲一卡2卡3卡4卡网站 |