5TE Soil moisture, Temperature and Conductivity Sensors Description:

User's Manual

The 5TE sensor determines soil moisture content, conductivity, and temperature at an oscillating frequency of 70MHz. The water content is determined by measuring the dielectric constant of the soil. The thermistor at the base of the triforked probe measures the soil temperature, and the conductivity is measured by screws in the middle of the surface of two of the probes. Background In 2006, Decagon developed 5TE by combining EC-5 and ECH2O-TE. Using the same theoretical basis as ECH2O-TE, 5TE can also measure soil moisture content, conductivity and temperature at the same time. The difference is that the 5TE uses stainless steel screws to determine the conductivity, while the ECH2O-TE uses gold-plated wire. In contrast, the 5TE is designed to be more robust and corrosion-resistant. In addition, 5TE uses a 5-point calibration of the dielectric constant, which is more accurate than the ECH2O-TE.

Measurement Theory

Volume moisture content 5TE The permittivity of the surrounding medium is determined by the principle of electromagnetic field. The sensor provides an oscillating electromagnetic wave of 70MHz, which charges the sensor according to the dielectric constant of the medium. The stored electricity is proportional to the dielectric constant and volumetric water content of the soil. The 5TE microprocessor measures the amount of charge and outputs the dielectric constant value. Temperature 5TE uses a thermistor mounted on the surface to measure temperature. It is located under the black plastic housing at the base of the forked probe, near one of the probes, and measures the temperature of the probe surface. 5TE normally outputs in °C, unless otherwise specified in the preferences file in the ECH2O DataTrac or ECH2O Utility program. It should be noted that if the black plastic housing at the base of the probe is in direct sunlight, the temperature reading will be very high. At the same time, direct sunlight can also seriously affect the service life of the sensor. It is recommended not to expose the plastic housing part to sunlight when installing the sensor.

EC

Electrical conductivity (EC) is an index used to characterize the ability of a substance to conduct current, and can be used to infer the content of polar molecules in a solution. The conductivity is determined by applying a changing current to the two electrodes to determine the impedance between the electrodes. The conductivity is equal to the reciprocal of the impedance multiplied by the unit constant (distance between electrodes/electrode area). 5TE determines EC using a dual probe array located on the stainless steel screws of two of the forked probes. The trace oil on the skin will greatly affect the accuracy of EC determination after contact with the screw. If this happens, please refer to the cleaning section at the end of the manual to clean the screws. 5TE measures the volume conductivity of the surrounding medium (bulk EC). The calibration values of bulk EC at the factory guarantee an accuracy of ±10% in the conductivity range of 0 to 7dS/m. This accuracy range fully meets most field, greenhouse and nursery measurements. However, the conductivity of soil with high salt content will be higher than the above calibration range. The measurement range of 5TE can be up to 23.1 dS/m bulk EC, when the bulk EC is higher than 7 dS/m, the user needs to calibrate. In addition, EC measurements above 7 dS/m are very sensitive to grease on the electrode surface. If you are measuring saline soil, be sure to read the sensor cleaning section at the end of the manual.

Data Acquisition Communication

When the excitation voltage is turned on, the 5TE is measured. Within the excitation time of 50ms, the 3 parameters were input in ASCII code. 1200 baud rate 8-bit asynchronous continuous output, none parity, one stop bit. Voltage range is 0-3.6V, transistor logic circuit. Power off during test interval. Three parameters are separated by Spaces in an ASCII data string. The data string ends with a carriage return. The first value is the original permittivity, the second is the original conductivity value, and the third is the original temperature value. The following shows how raw values are converted to standard unit values.

5TE Soil moisture, Temperature and Conductivity Sensors Specification:

Indicator Accracy Apparent permittivity (εa) : ±1εa (none units) from 1-40 (soil range), ± 15% from 40-80
Soil volumetric Water Content (VWC) : using the Topp equation: solution conductivity < Typical ±0.03 m3 / m3 (± 3% VWC) in 10 dS/m mineral soils using medium specific calibration, ± 0.01-0.02 m3 / m3 (± 1-2% VWC) in any porous medium
Electrical conductivity (EC) : ± 10% from 0 to 7 dS/m, user calibrated above 7 dS/m
Temperature: ±1°C
Precision specification εa: 0.1εa is 1-20, < 0.75εa is 20-80
VWC:0.0008m 3 / m 3(0.08%VWC),0 ~ 50%VWC
EC: 0.01dS/m, from 0 to 7dS/m, 0.05dS/m, from 7 to 23.1dS/m
Temperature: 0.1℃
Measuring range εa: 1 (air) ~ 80 (water)
EC: 0-23dS/m (body)
Temperature: -40-60 °C
Measured Time 150 ms
Sensor type VWC: frequency domain
EC: Two probe design
Temperature: Thermistor
Output RS232(TTL),SDI-12 ,RS485
Operating Environment -40° to 60 ° C
Power Supply 3.6-15 VDC, 0.3 mA static, 10 mA during 150 ms measurement
Cable Length The sensor comes standard with 5 meters of cable. Custom cable lengths are available. The maximum cable length is 75 m.
Cable connector type 3.5mm "stereo" plug, or strip tinned wire (3)
Sensor Sizes 10cm×3.2cm×0.7cm
Data Logger Em50,ProCheck,Campbell Scientific, SDI-12 Converter

Note: This product can be customized according to customer requirements interface (RS232/RS485), communication protocol (MODBUS), etc. In addition, the company has RS232/RS485 to SDI-12 module, which is convenient for customers to secondary development and debugging. Please click if necessarySDI-12 Converter to RS232 RS485

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com
主站蜘蛛池模板: 精品久久亚洲中文字幕 | 国产日产欧产精品精品 | 亚洲精品久久久打桩机小说 | 亚洲性色av性色在线观看 | 免费黄色大片网站 | 婷婷激情六月 | 免免费国产aaaaa片 | 国产精品345在线播放 | 一级做人爱c黑人影片 | 久久精品国产首页027007 | 国产极品久久 | 国产成人午夜福利免费无码r | 91禁蘑菇在线看 | 麻豆果冻国产剧情av在线播放 | 双乳奶水饱满少妇呻吟免费看 | 亚洲中文无码人a∨在线 | 国产特级毛片aaaaaa高潮流水 | 久久精品日本啪啪涩涩 | 九个美女露脸撒尿嘘嘘视频 | 国产成人精品亚洲男人的天堂 | 亚洲精品国产综合麻豆久久99 | 精品国产va久久久久久久 | 中文字幕一区二区三区日韩精品 | 国产乱人伦偷精品视频免 | 中文字幕日韩精品有码视频 | 日本福利视频一区 | 五月天国产精品 | 91风间由美一区二区三区四区 | 久久久久久久久久久91 | 最新精品国偷自产在线下载 | 在线中文字幕亚洲日韩2020 | 国产亚洲精品久久久久久老妇小说 | 亚洲伊人情人综合网站 | 小泽玛利亚一区二区免费 | 成人免费观看男女羞羞视频 | 国产一区二区在线免费 | 欧洲熟妇色xxxx欧美老妇 | 亚洲最大av一区二区三区 | 久久国产视频一区 | 99国产欧美精品久久久蜜芽 | 国产精品久久久久9999小说 | 五月婷婷激情视频 | www青青草 | 国产久爱免费精品视频 | 久久色婷婷 | av天天有 | 毛葺葺老太做受视频 | 欧美福利片在线观看 | 国产欧美日韩视频在线 | 欧美激情视频网站 | 激情黄色一级片 | 亚洲黄色在线 | 日产中文字幕在线精品一区 | 久久精品国产男包 | 成人传媒 | 久久久不卡国产精品一区二区 | 少妇裸体淫交免费视频网站 | 狠狠躁三区二区久久天天 | 卡1卡2卡三卡精品视频 | 亚洲熟妇中文字幕日产无码 | 久久免费资源 | 久色视频在线观看 | 成人做爰视频www网站 | 一级片免费 | 免费人成黄页在线观看国产 | 福利视频第一页 | 丝袜国产视频 | 亚洲一卡2卡三卡四卡精品 国产 日韩 欧美 成人 | 永久免费d站视频 | 久久精品伊人波多野结衣 | 久久久国产精品黄毛片 | 日韩va视频 | 亚洲在线不卡 | 在线日产精品一区 | 精品国产福利在线视频 | 天堂在线最新版资源www | 精品一区二区三区久久 | 国产激情久久久 | 日欧一片内射va在线影院 | www国产91| 亚洲涩涩在线 | 久热在线这里只有精品国产 | 就去干成人网 | 一级特黄少妇高清毛片 | 国产成a人亚洲精品无码久久网 | 性色av一区二区三区咪爱四虎 | 一本大道综合伊人精品热热 | 亚洲精品aa片在线观看国产 | 美女视频黄a视频全免费 | 亚洲精品国产美女久久久99 | 亚洲欧美一区二区成人片 | 小宝极品内射国产在线 | 少妇饥渴偷公乱75 | 国产精品合集久久久久青苹果 | 喷水在线观看 | 99av成人精品国语自产拍 | www.久久爱 | 香蕉av777xxx色综合一区 | 91插插插视频 |